Description

Capacities: 46 gph (1774 l/h) to 274.7 gph (1040 l/h)

Mechanical diaphragm pump, a maximum pressure of 174 psi and a stroke length of 1-100% (30% minimum recommend for most repeatable accuracy)

Liquid ends: PVT and SST

Basic Version:

Standard 56-C flange. (Motor not included)

Capacities: 46 gph (174 l/h) to 264.2 gph (1000 l/h)

Turndown : 100:1 with variable speed motor

Stroke frequency: Only with SCR or VFD

Control Version:

Includes 115/230 V motor

Capacities: 48.1 gph (182 l/h) to 274.7 gph (1040 lph)

Turndown: up to 2000:1

Stroke Frequency varies by model: digital from 1 to 90, 160, 200 spm

Manual, external contact pulse with multiplier/divieder and analog oeration, it displays gph (lph) and totalized flow (gallons and liters)

Flow verification with removable HMI unit with large illuminated LCD and a connection to PROFIBUS-DP interface

Integrated multilayer safety diaphragm (standard) with visual or electrical rupture indicator